Definition: Ambient or internal temperature is too high


Possible Causes: 

  1. Ambient temperature outside the inverter is too high
  2. Fan is blocked
  3. Convection airflow is insufficient due to improper installation.

Solutions:

  1. Confirm that external ambient temperature is within the specified range of operating temperature.
  2. Check whether air inlet is blocked
  3. Check whether fan is blocked
  4. Check whether the location of installation is appropriate or not
  5. Observe for 30 minutes and see whether the alarm will be eliminated automatically
  6. Contact after-sales service personnel