Error Code - 321 - Cabinet Over temperature - Alarm Severity Major

Alarm ID
Alarm Name
Alarm Severity
Possible Cause
Suggestion
321
Cabinet Over temperature
Major
Cause ID = 1
  • The SUN2000 is installed in a place with poor ventilation.
  • The ambient temperature exceeds the upper threshold.
  • The internal fan works abnormally.
1. Check the ventilation and ambient temperature of the SUN2000 installation position.
 2. If the ventilation is poor or the ambient temperature exceeds the upper threshold, improve the ventilation and heat dissipation.
3. If the ventilation and ambient temperature both meet requirements, contact Huawei technical support.